Please use this identifier to cite or link to this item: https://ir.iimcal.ac.in:8443/jspui/handle/123456789/1575
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRoy, Pranab
dc.contributor.authorBhattacharjee, Rupam
dc.contributor.authorRahaman, Hafizur
dc.contributor.authorDasgupta, Partha Sarathi
dc.date.accessioned2021-08-26T06:23:38Z-
dc.date.available2021-08-26T06:23:38Z-
dc.date.issued2012
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84867770888&doi=10.1109%2fISVLSI.2012.33&partnerID=40&md5=31c255e6ee17d84892fa767b3930b057
dc.identifier.urihttps://ir.iimcal.ac.in:8443/jspui/handle/123456789/1575-
dc.descriptionRoy, Pranab, School of VLSI Technology, Bengal Engineering and Science University, Shibpur, India; Bhattacharjee, Rupam, School of VLSI Technology, Bengal Engineering and Science University, Shibpur, India; Rahaman, Hafizur, School of VLSI Technology, Bengal Engineering and Science University, Shibpur, India; Dasgupta, Partha Sarathi, Indian Institute of Management, Calcutta, India
dc.descriptionISSN/ISBN - 978-076954767-1
dc.descriptionpp.320-325
dc.descriptionDOI - 10.1109/ISVLSI.2012.33
dc.description.abstractDigital micro fluidic biochips (DMFB) represent a new generation lab-on-a-chip architecture based upon micromanipulation of droplets via a programmed external electric field by an individually addressable 2D electrode array. DMFBs are classified as: Direct addressing and Cross-referencing biochips. Cross-referencing biochip technology scales down the number of pins per chip drastically, thereby reducing the costs of manufacturing and testing. However, these chips face a serious issue in terms of electrode interference during simultaneous routing of droplets. In this paper, we propose a routing-aware zone-based detailed placement scheme that rearranges the droplet locations on a pre-synthesized Bioassay schematic. The objectives of the proposed scheme include (i) an improved routing in respect of less overall routing time, more cell utilization, less crossover with intelligent collision avoidance, and (ii) enhanced pin sharing overcoming the major issue of electrode interference for Cross-referencing biochips. Simulations are carried out on four test benches of Benchmark suite III, and the results obtained are encouraging. © 2012 IEEE.
dc.publisherSCOPUS
dc.publisherProceedings - 2012 IEEE Computer Society Annual Symposium on VLSI, ISVLSI 2012
dc.subjectAlgorithms
dc.subjectCross-referencing Biochips
dc.subjectDigital Microfluidics
dc.subjectElectrode interference
dc.subjectPlacements
dc.subjectRouting
dc.titleA new algorithm for routing-aware net placement in cross-referencing digital microfluidic biochips
dc.typeConference Paper
Appears in Collections:Management Information Systems

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.